๐Ÿ”น High-Efficiency Filtration
  1. Equipped with HEPA / ULPA filtration systems to effectively capture airborne particles
  2. Ensures a high level of cleanliness and compliance with stringent cleanroom standards

๐Ÿ”น Stainless Steel Construction
  1. Constructed using SS 304 / SS 316 stainless steel or powder-coated GI
  2. Offers excellent durability, corrosion resistance, and easy maintenance
  3. Smooth surfaces prevent particle accumulation

๐Ÿ”น Advanced Control System
  1. Integrated microprocessor / PLC-based control system
  2. Enables precise operation and customization of parameters such as airflow velocity, cycle time, and door interlocking

๐Ÿ”น Two-Stage Entry System
  1. Designed with dual-door interlocking mechanism
  2. Ensures that only one door operates at a time
  3. Maintains a sealed and contamination-free environment

๐Ÿ”น Adjustable Airflow Velocity
  1. High-velocity airflow with adjustable settings
  2. Suitable for different cleanroom classifications and process requirements

๐Ÿ”น Occupancy Detection System
  1. Equipped with infrared occupancy sensors
  2. Automatically activates the air shower cycle upon entry

๐Ÿ”น Emergency Safety System
  1. Provided with emergency stop button
  2. Allows immediate shutdown in case of safety concerns

๐Ÿ”น User-Friendly Interface
  1. Modern touchscreen display panel
  2. Easy operation, monitoring, and system configuration

๐Ÿ”น High-Velocity Air Jets
  1. Strategically positioned adjustable air nozzles
  2. Deliver high-velocity filtered air to effectively remove contaminants from personnel and materials

๐Ÿ”น Filter Monitoring System
  1. Continuous monitoring of HEPA / ULPA filter performance
  2. Alerts for timely maintenance and replacement

๐Ÿ”น Customizable Cycle Time
  1. Adjustable decontamination cycle ranging from 10 to 30 seconds or as required
  2. Flexible operation based on contamination levels

๐Ÿ”น Alarm & Indication System
  1. Audio-visual alarms for:
    1. System faults
    2. Filter replacement alerts
    3. Door status indication

๐Ÿ”น Energy-Efficient Operation
  • Designed with energy-saving components
  • Optimized power consumption during operation and standby modes

๐Ÿ”น Compliance & Standards
  • Manufactured in compliance with ISO 14644 and GMP guidelines
  • Suitable for pharmaceutical, electronics, food, and biotechnology industries
๐Ÿ”น Construction Material
  • Internal and external construction made of high-grade Stainless Steel (SS 304 / SS 316) or powder-coated GI
  • Smooth, non-porous surfaces for easy cleaning and contamination control
  • Corrosion-resistant and durable structure suitable for cleanroom environments

๐Ÿ”น Filtration System
  • Equipped with HEPA filters (โ‰ฅ99.99% efficiency at 0.3 microns)
  • Optional ULPA filters (โ‰ฅ99.999% efficiency) for higher cleanliness classes
  • Pre-filters provided to enhance HEPA filter life and system efficiency

๐Ÿ”น Airflow & Velocity
  • High-velocity airflow ranging from 20 to 25 m/s
  • Uniform airflow distribution ensures effective particle removal
  • Adjustable airflow settings based on cleanroom classification

๐Ÿ”น Control System
  • Advanced Microprocessor / PLC-based control system
  • Ensures precise operation, monitoring, and automation
  • User-friendly interface for easy configuration

๐Ÿ”น Door Interlocking System
  • Dual-door (entry & exit) system with electromagnetic interlocking
  • Prevents simultaneous opening of both doors
  • Maintains pressure differential and contamination control

๐Ÿ”น Occupancy Sensor
  • Integrated infrared sensors detect personnel or material presence
  • Automatically initiates air shower cycle

๐Ÿ”น Emergency Safety Features
  • Emergency stop button provided inside the unit
  • Immediate shutdown capability for safety compliance

๐Ÿ”น User Interface
  • Modern touchscreen / digital display panel
  • Easy operation, monitoring, and parameter adjustments

๐Ÿ”น Adjustable Cycle Time
  • Programmable cycle duration ranging from 10 to 30 seconds
  • Customizable based on contamination level and process requirements

๐Ÿ”น Air Jet Nozzles
  • Stainless steel, adjustable high-velocity air nozzles
  • Strategically positioned for maximum cleaning efficiency
  • Uniform coverage across all directions

๐Ÿ”น Alarm System
  • Audio-visual alarms for:
    • Filter replacement alerts
    • Door status indication
    • System faults or malfunctions

๐Ÿ”น Electrical Requirements
  • Designed as per Indian electrical standards (230V / 415V, 50Hz)
  • Energy-efficient motor and blower system

๐Ÿ”น Dimensions
  • Standard and custom-built sizes available
  • Designed to fit cleanroom layouts and project-specific space constraints

๐Ÿ”น Compliance & Standards
  • Designed in accordance with ISO 14644 Cleanroom Standards
  • Suitable for pharmaceutical, electronics, food, and biotech industries
  • Meets GMP and regulatory requirements

๐Ÿ”น Optional Features
  • UV-C light sterilization system
  • Integration with access control systems
  • Remote monitoring and automation
  • VFD-based airflow control